APC Power Saving Back-UPS ES 8 Outlet 550VA 230V

SKU: APC-BE550G

APC Power Saving Back-UPS ES 8 Outlet 550VA 230V

More Views

  • Power-Saving Back-UPS ES 8 Outlet 550VA 230V
  • Adjustable voltage sensitivity
  • Audible alarms
  • Automatic self-test
  • Battery failure notification
  • Battery replacement without tools
  • Battery-protected and surge-only outlets
  • Cold-start capable
  • Data-line Protection
  • Hot-swappable batteries
  • Safety-agency approved
  • USB connectivity
  • User-replaceable batteries
Details
  • Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Provides notification of changing utility power and UPS power conditions
  • Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
  • Provides temporary battery power when the utility power is out.
  • Protection of data lines (Ethernet, Coaxial and Phone lines) ensures complete protection of your equipment from surges. It is very important to protect your equipment from “back door" electric surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines.
  • Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Provides management of the UPS via a USB port (not available on all models).
  • Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

UPS Promotion July 2016

Features

Protection

  • Battery and surge protected outlets:Back up and protect your hardware and data during power outages, surges and spikes.
  • Surge only outlets:Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Manageability

  • Audible alarms: Provides notification of changing utility power and UPS power conditions
  • LED status display: Quickly understand unit and power status with visual indicators.

Safety

  • Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Marketing Features

  • Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Availability

  • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Specifications

Output

  • Output power capacity:330 Watts / 550 VA
  • Max Configurable Power (Watts): 330 Watts / 550 VA
  • Nominal Output Voltage: 230V
  • Output Frequency (sync to mains): 47 - 63 Hz
  • Output Frequency (not synced):50Hz +/- 0.1% for 50Hz nominal
  • Other Output Voltages: 220
  • Topology: Standby
  • Waveform type:Stepped approximation to a sinewave
  • Output Connections:
    • (4) Australian (selector_surgetitle)
    • (4) Australian (Battery Backup)
  • Output Voltage Tolerance: +/- 5% static and 100% load step
  • Transfer Time: 6ms typical: 10ms maximum

Input

  • Nominal Input Voltage:230V
  • Input frequency: 50/60 Hz
  • Input Connections: Australian/Chinese
  • Cord Length: 1.83 meters
  • Maximum Input Current: 10.0 A

Batteries & Runtime

  • Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
  • Typical recharge time: 16 hour(s)
  • Replacement Battery: APCRBC110
  • Battery Volt-Amp-Hour Capacity: 86
  • Runtime: View Runtime Graph
  • Efficiency: View Efficiency Graph

Communications & Management

  • Control panel: LED status display with On Line: On Battery: Replace Battery and Overload indicators

Surge Protection and Filtering

  • Surge energy rating: 310 Joules
  • Data Line Protection: Analog phone line for phone/fax/modem/DSL (RJ-45 connector), Network line - 10/100 Base-T Ethernet (RJ-45 connector)
  • Filtering:Full time multi-pole noise filtering: 5% IEEE surge let-through: zero clamping response time: meets UL 1449

Physical

  • Maximum Height: 88, 8.8 cm
  • Maximum Width: 180, 18.0 cm
  • Maximum Depth: 302, 30.2 cm
  • Net Weight: 5.5 kg
  • Shipping weight: 6.2 kg
  • Shipping Height: 128, 12.8 cm
  • Shipping Width: 235, 23.5 cm
  • Shipping Depth: 393, 39.3 cm
  • Color: Black
  • Master Carton Dimensions (Length x Width x Height): 405
  • Master Carton Units: 2.0
  • Master Carton Weight: 13.0
  • Pallet Dimensions: 48 inches
  • # of Layers per Pallet: 4.0
  • # of Units per Layer per Pallet: 20.0
  • Pallet Weight: 1230.0 lbs.
  • Units per Pallet: 48.0
  • SCC Codes: 1073130427541 8

Environmental

  • Operating Environment: 0 - 40 °C
  • Operating Relative Humidity: 0 - 95 %
  • Operating Elevation: 0-9000 meters
  • Storage Temperature: -15 - 40 °C
  • Storage Relative Humidity: 0 - 95 %
  • Storage Elevation: 0-9000 meters
  • Audible noise at 1 meter from surface of unit: 40.0 dBA

Conformance

  • Approvals: A-tick, C-tick, CE, Telepermit
  • Equipment protection policy: Lifetime: 150000 AUD
  • Standard warranty: 2 years repair or replace

Sustainable Offer Status

  • RoHS:Compliant
  • REACH:REACH: Contains No SVHCs
  • PEP:Available in Documentation